{"id":76366,"date":"2026-03-06T06:06:31","date_gmt":"2026-03-06T06:06:31","guid":{"rendered":"https:\/\/teeptrak.com\/oee-data-reliability-common-measurement-errors-and-solutions-2\/"},"modified":"2026-03-06T06:06:31","modified_gmt":"2026-03-06T06:06:31","slug":"oee-data-reliability-common-measurement-errors-and-solutions-2","status":"publish","type":"post","link":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/","title":{"rendered":"OEE Data Reliability: Common Measurement Errors and Solutions"},"content":{"rendered":"<div class=\"et_pb_section et_pb_section_7 et_section_regular\" >\n<div class=\"et_pb_row et_pb_row_10\">\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_column_10  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">The quality of your decisions depends on the quality of your data. OEE calculated on erroneous information produces false analyses and misdirected actions. Yet many companies work with approximate OEE data without even realizing it. In this article, we identify the most common measurement errors and share concrete solutions to ensure reliable performance tracking. From IoT sensors to operator training, discover how to guarantee the accuracy of your indicators and obtain high-quality data.<\/p>\n<p><strong>Table of contents:<\/strong><\/p>\n<ol>\n<li>\n<p>Consequences of poor data quality<\/p>\n<\/li>\n<li>\n<p>Common measurement errors<\/p>\n<\/li>\n<li>\n<p>Methodology to ensure reliable data<\/p>\n<\/li>\n<li>\n<p>Data governance and quality controls<\/p>\n<\/li>\n<li>\n<p>Continuous improvement of reliability<\/p>\n<\/li>\n<\/ol>\n<h2>Consequences of Poor OEE Data Quality<\/h2>\n<p>An OEE displayed at 72% is reassuring. But if this figure is based on under-reported downtime or obsolete theoretical rates, it doesn&#8217;t reflect reality. Poor data quality leads to false analyses. Teams think they&#8217;re performing correctly while improvement opportunities remain invisible. The consequences are direct: the wrong levers are activated while real problems persist.<\/p>\n<p>This situation repeats in many organizations. Dashboards display results, production meetings follow one another, but nothing really improves. Decision-making is based on thin air. No analysis can compensate for erroneous measurement at the source, and indicator credibility collapses among field teams.<\/p>\n<p>A 5-minute error on a downtime event seems negligible. Multiplied by ten daily events across twenty machines over a year, it represents hundreds of phantom hours. These cumulative deviations distort problem prioritization and impact your competitiveness. Delivery times drift, customer confidence erodes. OEE data integrity tolerates no approximation. The necessity to invest in data quality before analysis constitutes the foundation of any serious project. Without this, innovation remains blocked by unstable foundations.<\/p>\n<h2>Common Measurement Errors: Problem Structure<\/h2>\n<h3>Manual Data Entry and Its Limitations<\/h3>\n<p>Manual collection of downtime data remains the number one source of error. Operators estimate duration from memory, round generously, or simply forget to declare certain events. Micro-stops under five minutes systematically fall through the cracks. These small accumulated losses often represent 10 to 15% of production time.<\/p>\n<p>Human bias aggravates the problem. Nobody likes to declare stops on their machine. Consciously or not, durations are reduced and causes simplified. The &#8220;miscellaneous&#8221; category explodes, making any analysis impossible. Without data validity, continuous improvement becomes wishful thinking and data consistency disappears.<\/p>\n<h3>Obsolete Theoretical Rates<\/h3>\n<p>OEE performance calculation relies on a theoretical reference rate. If this rate dates from machine commissioning fifteen years ago, it no longer reflects reality. Tooling modifications, material changes, or equipment wear have evolved actual speed.<\/p>\n<p>A theoretical rate that&#8217;s too low masks slowdowns. A rate that&#8217;s too high generates performance above 100%, an obvious signal of incorrect parameterization. This step of regular rate revision by product and machine constitutes a prerequisite often neglected by companies.<\/p>\n<h3>Confusion in Stop Classification<\/h3>\n<p>Planned or unplanned stop? Breakdown or adjustment? Material wait or quality wait? These distinctions condition analysis but remain vague. The same event can be classified differently depending on the operator, team, or timing. This inconsistent structure pollutes your data stack.<\/p>\n<p>Stop Paretos mix incomparable categories. Action plans target symptoms rather than causes. Without clear nomenclature, each analysis starts from scratch. Event traceability becomes impossible and data control loses its meaning.<\/p>\n<h2>Methodology to Ensure Reliable Data<\/h2>\n<h3>Automate Collection with IoT Sensors<\/h3>\n<p>IoT sensors eliminate the human factor from data collection. They automatically detect machine cycles, stops, and restarts. No more approximate manual entry, no more oversights. Raw data arrives directly in the system without intermediary, guaranteeing integrity at the source.<\/p>\n<p>This automation often reveals a different reality from manual declarations. Micro-stops appear, actual durations display. After the initial shock, teams finally have a reliable basis for action. Data reliability through IoT sensors transforms quality in just a few installation days. This is the first step toward proper data management.<\/p>\n<h3>Define Validation Rules and Revise Parameters<\/h3>\n<p>A standardized list of stop causes eliminates ambiguities. Validation rules must define each category precisely with concrete examples. Operators must be able to classify any event without hesitation or personal interpretation. This methodology requires collaborative work with the field. Building classification together ensures its adoption. These best practices guarantee input compliance with defined standards.<\/p>\n<p>Theoretical rates and cycle times deserve minimum annual review. With each significant equipment modification, verify parameter relevance. Regular validation of references and their documentation ensure historical traceability. Data processing must include this systematic verification. A systematic deviation signals a parameter to correct in your data warehouse.<\/p>\n<h2>Data Governance and Quality Controls<\/h2>\n<h3>Implement Data Governance<\/h3>\n<p>OEE data management requires structured data governance. Define responsibilities: who validates parameters, who corrects anomalies, who audits quality. Without a designated owner, errors persist indefinitely. Each organization must adapt this governance to its structure and mobilize necessary resources.<\/p>\n<p>Data security and data protection are part of this governance. Who can modify reference rates? Who accesses raw data? These security rules protect system integrity against unauthorized modifications. Transparency on these rules strengthens team buy-in.<\/p>\n<h3>Implement Automatic Quality Controls<\/h3>\n<p>Simple quality controls detect obvious errors: 24-hour stop on a machine that produced, performance above 120%, negative cycle time. These automatic controls immediately alert on aberrant data and guarantee data consistency. Reliable data usage depends on this responsiveness.<\/p>\n<p>Configure these alerts for immediate notification. An error corrected the same day preserves context. Comparative analysis between similar teams or machines also highlights systematic anomalies. Question deviations without accusing. Correct the process before training people. Regular data control reveals biases to correct.<\/p>\n<h2>Continuous Improvement of Data Reliability<\/h2>\n<p>Technology isn&#8217;t enough. Even with IoT sensors, part of qualification remains manual. Operators must understand why precision matters. This training explains the link between data and decisions, between precision and improvement. An operator who sees their entries transform into concrete actions becomes aware of their role. These best practices anchor in company culture with time and management consistency.<\/p>\n<p>What isn&#8217;t measured doesn&#8217;t improve. Define data quality indicators: complete entry rates, stop qualification delays, percentage of aberrant data detected. Track these metrics as you track OEE itself. This approach transforms data quality into a managed objective. Progress becomes visible, drifts are detected. Continuous improvement also applies to your data, not just your machines.<\/p>\n<h2>Conclusion: Reliable Data as Foundation<\/h2>\n<p>OEE data reliability conditions everything else. False indicators produce false analyses. Data governance, automatic quality controls, and team training constitute the pillars of effective data management.<\/p>\n<p>IoT sensors automate collection and eliminate approximations. Clear methodology standardizes classifications. Regularly revised parameters guarantee calculation relevance. With these foundations in place, your data finally becomes exploitable for continuous improvement.<\/p>\n<p>This is the difference between flying by sight and flying by instruments. Your decisions gain credibility, your competitiveness strengthens, and innovation can finally rely on solid foundations.<\/p>\n<p>&nbsp;<\/p>\n<h2>FAQ: Frequently Asked Questions on OEE Data Reliability<\/h2>\n<\/div><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"et_pb_row et_pb_row_11\">\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_column_11  et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_accordion et_pb_accordion_5\">\n<div class=\"et_pb_toggle et_pb_module et_pb_accordion_item et_pb_accordion_item_24  et_pb_toggle_open\">\n<h5 class=\"et_pb_toggle_title\">How can I tell if my OEE data is reliable?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">Compare your declared data to field measurements. Time a few stops manually and compare to records. If deviations exceed 10%, your data has a problem. Performance above 100% also signals incorrect parameterization.<\/p>\n<\/div><\/div>\n<div class=\"et_pb_toggle et_pb_module et_pb_accordion_item et_pb_accordion_item_25  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">Do IoT sensors eliminate all errors?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">IoT sensors ensure reliable collection of times and quantities, but cause qualification often remains manual. A stop is detected automatically, its cause must be entered by the operator. The combination of sensors and guided entry offers the best compromise.<\/p>\n<\/div><\/div>\n<div class=\"et_pb_toggle et_pb_module et_pb_accordion_item et_pb_accordion_item_26  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">How many stop categories should be defined?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">Between 15 and 25 categories offer good balance. Fewer than 10 lack precision. More than 30 discourage entry. Test your nomenclature with operators before finalizing it.<\/p>\n<\/div><\/div>\n<div class=\"et_pb_toggle et_pb_module et_pb_accordion_item et_pb_accordion_item_27  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">How often should theoretical rates be revised?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">Annual review constitutes the minimum. Also trigger revision after each significant modification. Systematically document values and update dates for traceability.<\/p>\n<\/div><\/div>\n<div class=\"et_pb_toggle et_pb_module et_pb_accordion_item et_pb_accordion_item_28  et_pb_toggle_close\">\n<h5 class=\"et_pb_toggle_title\">What to do when teams resist transparency?<\/h5>\n<div class=\"et_pb_toggle_content clearfix\">\n<p data-pm-slice=\"1 1 &#091;&#093;\">Resistance often comes from fear of judgment. Position data as an improvement tool, not surveillance. Value progress rather than pointing out gaps. Transparency builds with management consistency.<\/p>\n<\/div><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The quality of your decisions depends on the quality of your data. OEE calculated on erroneous information produces false analyses and misdirected actions. Yet many companies work with approximate OEE data without even realizing it. In this article, we identify the most common measurement errors and [&hellip;]<\/p>\n","protected":false},"author":384731,"featured_media":0,"comment_status":"","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","ai_seo_title":"","ai_meta_description":"","ai_focus_keyword":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-76366","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential\" \/>\n<meta property=\"og:description\" content=\"The quality of your decisions depends on the quality of your data. OEE calculated on erroneous information produces false analyses and misdirected actions. Yet many companies work with approximate OEE data without even realizing it. In this article, we identify the most common measurement errors and [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/\" \/>\n<meta property=\"og:site_name\" content=\"TEEPTRAK - Connect to your industrial potential\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-06T06:06:31+00:00\" \/>\n<meta name=\"author\" content=\"Ravinder Singh\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ravinder Singh\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/\"},\"author\":{\"name\":\"Ravinder Singh\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#\\\/schema\\\/person\\\/d96426188e0e94087293348d88b3b586\"},\"headline\":\"OEE Data Reliability: Common Measurement Errors and Solutions\",\"datePublished\":\"2026-03-06T06:06:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/\"},\"wordCount\":1291,\"publisher\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#organization\"},\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/\",\"url\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/\",\"name\":\"OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#website\"},\"datePublished\":\"2026-03-06T06:06:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/oee-data-reliability-common-measurement-errors-and-solutions-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"OEE Data Reliability: Common Measurement Errors and Solutions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/\",\"name\":\"TEEPTRAK\",\"description\":\"TEEPTRAK official website - OEE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#organization\",\"name\":\"TEEPTRAK\",\"url\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.teepchina.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/cropped-Capture-decran-2023-05-04-112832.png\",\"contentUrl\":\"https:\\\/\\\/www.teepchina.com\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/cropped-Capture-decran-2023-05-04-112832.png\",\"width\":512,\"height\":512,\"caption\":\"TEEPTRAK\"},\"image\":{\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/teeptrak\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/teeptrakinternational\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/#\\\/schema\\\/person\\\/d96426188e0e94087293348d88b3b586\",\"name\":\"Ravinder Singh\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g\",\"caption\":\"Ravinder Singh\"},\"url\":\"https:\\\/\\\/www.teepchina.com\\\/en\\\/author\\\/ravinder-teeptrak\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/","og_locale":"en_US","og_type":"article","og_title":"OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential","og_description":"The quality of your decisions depends on the quality of your data. OEE calculated on erroneous information produces false analyses and misdirected actions. Yet many companies work with approximate OEE data without even realizing it. In this article, we identify the most common measurement errors and [&hellip;]","og_url":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/","og_site_name":"TEEPTRAK - Connect to your industrial potential","article_published_time":"2026-03-06T06:06:31+00:00","author":"Ravinder Singh","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Ravinder Singh","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/#article","isPartOf":{"@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/"},"author":{"name":"Ravinder Singh","@id":"https:\/\/www.teepchina.com\/en\/#\/schema\/person\/d96426188e0e94087293348d88b3b586"},"headline":"OEE Data Reliability: Common Measurement Errors and Solutions","datePublished":"2026-03-06T06:06:31+00:00","mainEntityOfPage":{"@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/"},"wordCount":1291,"publisher":{"@id":"https:\/\/www.teepchina.com\/en\/#organization"},"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/","url":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/","name":"OEE Data Reliability: Common Measurement Errors and Solutions - TEEPTRAK - Connect to your industrial potential","isPartOf":{"@id":"https:\/\/www.teepchina.com\/en\/#website"},"datePublished":"2026-03-06T06:06:31+00:00","breadcrumb":{"@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.teepchina.com\/en\/oee-data-reliability-common-measurement-errors-and-solutions-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.teepchina.com\/en\/"},{"@type":"ListItem","position":2,"name":"OEE Data Reliability: Common Measurement Errors and Solutions"}]},{"@type":"WebSite","@id":"https:\/\/www.teepchina.com\/en\/#website","url":"https:\/\/www.teepchina.com\/en\/","name":"TEEPTRAK","description":"TEEPTRAK official website - OEE","publisher":{"@id":"https:\/\/www.teepchina.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.teepchina.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.teepchina.com\/en\/#organization","name":"TEEPTRAK","url":"https:\/\/www.teepchina.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.teepchina.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.teepchina.com\/wp-content\/uploads\/2023\/05\/cropped-Capture-decran-2023-05-04-112832.png","contentUrl":"https:\/\/www.teepchina.com\/wp-content\/uploads\/2023\/05\/cropped-Capture-decran-2023-05-04-112832.png","width":512,"height":512,"caption":"TEEPTRAK"},"image":{"@id":"https:\/\/www.teepchina.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/teeptrak\/","https:\/\/www.linkedin.com\/company\/teeptrakinternational\/"]},{"@type":"Person","@id":"https:\/\/www.teepchina.com\/en\/#\/schema\/person\/d96426188e0e94087293348d88b3b586","name":"Ravinder Singh","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/afa004471ac2dcd20a0bfe626e1cfd4d06876c592f2b766fca708c3d717a3d13?s=96&d=mm&r=g","caption":"Ravinder Singh"},"url":"https:\/\/www.teepchina.com\/en\/author\/ravinder-teeptrak\/"}]}},"_links":{"self":[{"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/posts\/76366","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/users\/384731"}],"replies":[{"embeddable":true,"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/comments?post=76366"}],"version-history":[{"count":0,"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/posts\/76366\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/media?parent=76366"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/categories?post=76366"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.teepchina.com\/en\/wp-json\/wp\/v2\/tags?post=76366"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}